Bio-Gas UNITS  >   PRE-TREATMENT

 

<!-- 91 -->
PRE-TREATMENT

Biokomp’s portfolio of low-pressure gas treatment solutions makes full use of our expertise in process design and engineering to provide the gas at the physical and chemical conditions demanded by the customer’s specific application.
The range of available solutions includes different processing units designed to remove impurities and separate fluids from the raw gas, as specified below:

SULPHUR REMOVAL
Complete desulfurization plants, for deep removal of hydrogen sulphide (H2S).
SILOXANE REMOVAL
Special reactors for siloxanes removal by activated carbon adsorption.
DEWATERING
Gas/Liquid separators, gravel filters, and dehumidification skids with refrigerated water chillers.
DEDUSTING
Fine and ultrafine gas filtration systems, including ceramic candle filters, for simultaneous removal of particulate, dust and acid gases.

If you are planning to install one of the following units in your plant, please enter the technical data given in the fields below to submit your enquiry to us. If you need further assistance, feel free to contact us to find out more and receive full information.

CLICK TO OPEN THE DATA ENTRY FORM
checked   SULPHUR REMOVAL   
checked   SILOXANE REMOVAL   
checked   DEWATERING   
checked   DEDUSTING   

 

up-and-shutSULPHUR REMOVAL

Max flow rate - Nm³/h (*)

Gas inlet pressure - bar(g) (*)

Gas inlet temperature average - °C (*)

Ambient temperature, Min - °C (*)

Ambient temperature, Max - °C (*)

Gas humidity - %

Max H₂S content at the inlet - ppm Vol(*)

Max H₂S content at the outlet - ppm Vol(*)

Quantity (*)

Note

 

 

up-and-shutSILOXANE REMOVAL

Max flow rate - Nm³/h (*)

Gas inlet pressure - bar(g) (*)

Gas inlet temperature average - °C (*)

Ambient temperature, Min - °C (*)

Ambient temperature, Max - °C (*)

Max Siloxane content at the inlet - mg/m3 (*)

Max Siloxane content at the inlet - mg/m3 (*)

Quantity (*)

Note

 

 

up-and-shutDEWATERING

Max flow rate - Nm³/h (*)

Gas inlet pressure - bar(g) (*)

Gas inlet temperature - °C (*)

Ambient temperature, Min - °C(*)

Ambient temperature, Max - °C(*)

Relative humidity at max temperature - %(*)

Water dew point at the inlet - °C (*)

Water dew point at outlet - °C (*)

Quantity (*)

Note

 

 

up-and-shutDEDUSTING

Max flow rate - Nm³/h (*)

Gas inlet pressure - bar(g) (*)

Ambient temperature, Min - °C(*)

Ambient temperature, Max - °C(*)

Relative humidity at max temperature - %

Particle size at the inlet - micron (*)

Dust fraction at the inlet - % Vol (*)

Max particle size at the outlet - micron (*)

Quantity (*)

Note